We carry: SH-500, SH-1000, SH-2500, SH-2000, SH-4000
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
Model
|

SH-500
|

SH-1000
|

SH-2500
|

SH-2000
|

SH-4000
|
|
Heating Capacity BTU/h
|
100,000-500,000
|
400,000-1,000,000
|
750,000-2,500,000
|
400,000-2,000,000
|
1,750,000-4,000,000
|
|
Fuel Type
|
LP/NG
|
LP/NG
|
LP/NG
|
LP/NG
|
LP/NG
|
|
Max. Fuel Useage/Hr
|
5.46 gal. or
5 therms
|
10.9 gal. or
10 therms
|
25 gal. or
25 therms
|
21.84 gal. or
20 therms
|
43.67 gal. or
40 therms
|
|
CFM
|
4,600
|
5,250
|
10,000
|
10,750
|
22,250
|
|
Electrical Requirements
|
115v, 1 phase
7 amps
|
115v, 1 phase
13 amps
|
208/230v, 1 phase
11/12.2 amps
|
230/460v, 3 phase
14/7 amps
|
230/460v
3 phase
40/20 amps
|
|
Motor/HP
|
1/2
|
1
|
2
|
5
|
15
|
|
Dimensions HxLxW (In.)
|
30×42x20
|
33×48x22
|
37×58x29
|
54×105x48
|
79×132x64
|
|
Weight – lbs.
|
135
|
195
|
250
|
750
|
1,250
|
|
Certifications
|
CSA/AGA
|
CSA/AGA
|
CSA/AGA
|
CSA/AGA
|
CSA/AGA
|
SH-500 (100,000 – 500,000 BTUs/hr. )
Portable Construction Heater
 |
The SH-500 portable construction heater has an effective heating range between 100,000 – 500,000 BTUs/hr. Special safety features include our patented 100% stainless steel burner with exclusive inner-lined heat shield that maintains a cool outer shell and a red indicator light located near the on/off switch to warn of potential problems. An enclosed fan-cooled industrial motor drives an eight-blade, high-efficiency axial propeller, maintaining air movement through higher static pressures. Large diameter wheels and rubber-gripped handles provide easy handling and maximum portability. |
SH-1000 (400,000 – 1,000,000 BTUs/hr.)
Portable Construction Heater
 |
The SH-1000 portable construction heater has an effective heating range between 400,000 – 1,000,000 BTUs/h For maximum efficiency, this model maintains a lower discharge temperature of 100-220 degrees F to achieve optimal air mixing and reduced stratification. An enclosed fan-cooled industrial motor drives an eight-blade, high-efficiency axial propeller, maintaining air movement through higher static pressures. Safety features include our exclusive inner-lined heat shield that maintains a cool outer shell and a red indicator light located near the on/off switch to warn of potential problems. |
SH-2500 (750,000 – 2,500,000 BTUs/hr.)
Portable Construction Heater
 |
The SH-2500 portable construction heater has an effective heating range between 750,000 – 2,500,000 BTUs/hr. For maximum efficiency, this model maintains a lower discharge temperature of 100-220 degrees F to achieve optimal air mixing and reduced stratification. An enclosed fan-cooled industrial motor drives an eight-blade, high-efficiency axial propeller, maintaining air movement through higher static pressures. Safety features include our exclusive inner-lined heat shield that maintains a cool outer shell and a red indicator light located near the on/off switch to warn of potential problems. |
SH-2000 (2,000,000 BTUs/hr.)
Portable Industrial Heater
|
The SH-2000 portable industrial heater can supply up to 2,000,000 BTUs/h of heat, providing maximum heating for your construction site or warehouse facility. The stainless steel burner with a design-proven electronic ignition ensures complete combustion, and the reinforced structural steel frame allows complete mobility of the units. Special safety features include our exclusive inner-lined heat shield that maintains a cool outer shell and a red indicator light located near the on/off switch to warn of potential problems. A durable two-stage enamel paint finish withstands harsh industrial and construction conditions, and grills and heat shields are painted bright yellow for safety.
|
SH-4000 (4,000,000 BTUs/hr.)
Portable Industrial Heater
|
The SH-4000 portable industrial heater provides maximum heating for your construction site or warehouse facility, by supplying up to 4,000,000 BTUs/hr. of heating power. The stainless steel burner with a design-proven electronic ignition ensures complete combustion, and the reinforced structural steel frame allows complete mobility of the units. Special safety features include our exclusive inner-lined heat shield that maintains a cool outer shell and a red indicator light located near the on/off switch to warn of potential problems. A durable two-stage enamel paint finish withstands harsh industrial and construction conditions, and grills and heat shields are painted bright yellow for safety. |